![]() ![]() You will need to restore this address once the WebMon Enterprise Edition is set up.Į. NOTE: Document the IP address currently in use in your computer. ![]() Click on the radio button marked “Use the following IP address”. This will bring you to the Internet Protocol TCP/IP properties screen as seen in Fig. Select Internet Protocol TCP/IP and then click Properties. Clicking on Network Connections will bring you to the Network Connections screen as seen in Fig. On your computer, click Start, Control Panel, Network Connections. An alternative is to connect a PC directly to the WEBMON Enterprise LAN1 connection using a crossover cable for initial setup purposes. This connection needs to be a live internet or LAN connection. You will need this serial number to determine the pre-installed default IP address. Document the serial number printed on the label. The serial number is written on a label on the inside of the Web-Mon Enterprise. (See separate wiring guide to locate LAN1 input) a. E-Mon 1.Ĭonnect your internet or LAN to the Web-Mon Enterprise Edition’s LAN1 input with a standard Ethernet cable. Detailed descriptions of all the screens and capabilities of the Web-Mon are covered in the main Web-Mon Enterprise Edition guide, which is available as a PDF file on-line at We hope your experience with this product is an easy one and that it provides you with the information your need to make profitable choices regarding your energy use. Not all scenarios are covered in this Quick start guide. This quick start guide covers the basic set up and connection steps to get your Web-Mon Enterprise Edition up and running. Once you are set up, all you need to do to see your energy usage is to go to the Web-Mon Enterprise Edition’s web address and you will be connected directly to the Web-Mon Enterprise Edition and all the meters connected to it- no web host, no intermediaries, just you in direct and instant touch with the information you require to make wise energy decisions. All of these features are available on the Web-Mon Enterprise Edition’s built-in web pages. The Web-Mon is capable of storing and displaying kWh, demand kW data, graphs of kWh and kW, CO2 equivalents for the kWh, and many other features. The Web-Mon Enterprise Edition is a web enabled device that allows users to access meter data via the public internet or on a private network (LAN). 1.0 5/21/09 Thank you for choosing to purchase the Web-Mon Enterprise Edition from E-Mon. WEB-MON ENTERPRISE EDITION SETUP E-Mon Web-Mon Enterprise Edition Setup Ver. To navigate to a meters dashboard, in the global overview, simply double click on a meters name to view the meters dashboard view. The new meters that are added to the Report Builder appear in the global meter overview. Navigating to the fourth drop down menu view (User_Home_Page) provides a standard users view of the Utility-Server. Simply drag and drop a meter to the report and then save the modification. The third dialog view (ReportBuilder) is utilized to create the global meter overview and device navigation. For additional meters, copy a new meter from the palette on the left and paste it to the Modbus network and set the IP address and enable the new meter.įig. Simply double click the default template meter and utilizing the configuration dialog, rename the meter as desired and assign the meters IP address and set the meter to (enabled). The second dialog view (ModbusNetManager) provides the user with the ability to add meters, rename meters and configure the meters network IP address. ![]() The first view available in the drop down menu (AdministrationHome) is an Admin Users view that provides maintenance and administration functions such as server IP address administration, user administration, weather service configuration and more.įig. Navigation is accomplished via the upper left drop down menu.įig. The configuration home page provides the status of the Modbus driver and the ability to change the configuration users password. The log-in credentials are as follows: User Name = User Password = user User Name = AdminUser Password = adminuser User Name = SiteBuilder Password = sitebuilder NOTE: Log-in credentials are case sensitive.įig. The Utility-Server has three log-in categories, a standard user log-in, an administrators log-in and a configuration user log-in. The server serial number can be found on the server shipping box, or under the cover of the server unit.įig. Open a web browser and type in the server IP address such as, where the "X" is the last digit of the server serial number. 3.Ĭonnect a Cat5 crossover cable to the primary IP port on the server. FOR UTILITY-SERVER Configuration and User Guide Server/Laptop -PC connection An initial connection to the Utility-Server is made using a Cat5 IP crossover cable. Web-Mon Set Up Guide INSTALLATION INSTRUCTIONSĮ-Mon 1985 Douglas Drive North Golden Valley, MN 55422 (800) 334-3666 ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |